Protective coating applied to structural steel in Regal's coating shop
Passive fire protection for structural steel

SHOP APPLIED INTUMESCENT FIREPROOFING

SPECIFICATION-DRIVEN FIRE PROTECTION

Shop applied intumescent fireproofing for structural steel, coordinated around the approved fire-resistance design, coating system, required thickness and finish.

Explore Service

SHOP APPLIED

Controlled application environment

DOCUMENTED

Thickness and inspection records

SYSTEM BASED

Applied to the approved design

Service overview

Intumescent Fireproofing Applied Around the Approved Design

Intumescent coatings react to heat by expanding into an insulating char that helps protect structural steel for the fire-resistance period defined by the approved assembly. Product selection and required thickness depend on the listed design, steel geometry, section factor, exposure conditions and specified finish.

Regal coordinates surface preparation, compatible primer review, intumescent application, environmental monitoring and inspection in a controlled shop workflow. Project-specific listings, products, thicknesses and acceptance requirements are confirmed from the governing documents before production begins.

Project value

Benefits Built Into the Program

Controlled Application

Shop conditions support coordinated surface preparation, environmental monitoring, application windows and cure requirements before steel reaches the jobsite.

Design Coordination

The coating system, primer compatibility, required thickness and finish are reviewed against the approved fire-resistance design and project specification.

Documented Inspection

Application records and thickness checks provide traceability for the project team and required acceptance process.

Execution

Application and Inspection Methods

1

Design and Submittal Review

Confirm the listed assembly, steel members, section factors, primer, intumescent product, finish coat, required rating and inspection requirements.

2

Surface and Primer Preparation

Prepare the steel and apply or verify the compatible primer system in accordance with the approved product and project requirements.

3

Intumescent Application

Apply the specified material in controlled passes while monitoring ambient conditions, recoat windows and wet-film build.

4

Thickness Verification

Verify dry-film thickness by member or design requirement, document approved repairs and release finished steel for protected handling and shipment.

Representative Applications

Typical project types supported by this service include:

Structural columns and beams
Commercial and institutional steel
Industrial structures
Architecturally exposed structural steel
Interior structural framing
Steel requiring a specified fire-resistance rating

Plan Your Next Coating Project

Send the approved fire-resistance design, steel schedule, section sizes, coating specification, primer details, finish requirements and delivery schedule for review.